    FL(R)N36-24kv indoor high-voltage SF6 load circuit breaker is an indoor switchgear with a rated voltage of 24KV. It uses SF6 gas as arc extinguishing and insulation medium. It includes three positions: closing, opening and grounding. It has the characteristics of small size, easy installation and use, and strong environmental adaptability.
  • compartilhar:
  • Contate-nos Solicitação on-line
  • Correspondência:ansel@apexe.cc

FLN36-24KV High Voltage SF6 Load Break Switch Spacing 230mm



1.FL(R)N36-24KV indoor high-voltage SF6 load circuit breaker is an indoor Switchgear with a rated voltage of 24KV  It uses SF6 gas as arc extinguishing and insulation medium. It includes three positions: closing, opening and grounding. It has the characteristics of small size, easy installation and use, and strong environmental adaptability.


2.Combining FL(R)N36-24KV indoor high-voltage SF6 load circuit breaker with other electrical components can realize control and protection functions. It can be used for control and protection of electrical equipment in industrial and mining enterprises, civil power supply and secondary substations. Among them, the load switch-fuse combination electrical appliance matches the Transformer protection characteristics, which is particularly suitable for ring network power supply units.


3.FLN36-24KV/630-20 indoor high-voltage SF6 load circuit breaker (hereinafter referred to as load switch) and FL(R)N36-24KV/100-50 combination electrical appliance (hereinafter referred to as combination electrical appliance) comply with national standards GB3804 “3~63KV AC high-voltage load switch” (EQVIEC60265-1) and GBL6926 “AC high-voltage load switch-fuse combination electrical appliance” (EQVIEC420).


Operating environment


● Altitude: The maximum altitude of the equipment installation site is 1000m;

● Ambient air temperature: upper limit +40C, lower limit -15C;

● Ambient humidity: daily average relative humidity is not more than 95%, monthly average relative humidity is not more than 90%;

Earthquake: earthquake intensity does not exceed 8 degrees;

● Ambient air should not be obviously polluted by corrosive and flammable gases, water vapor, etc., and there should be no frequent severe vibrations.


No.ItemUnitData
1Rated voltageKV24
2Rated frequencyHz50
3Rated currentA630
4Rated peak withstand currentKA50
54s rated short time withstand currentKA20
6Rated making currentKA50
7Rated breaking
current
Active load breaking currentKA630
Breaking current loopA630
Cable charging breaking currentA10
81  min power frequency withstand voltage(phase to
phase,to earth,fracture)
KV42/48
9Lightning impulse withstand voltage(phase to
phase,to earth,fracture)
KV75/85
10Relative pressure of SF6 gas(20C Gp)MPa≤0.04
11Rated operating voltage (electric)VAC220、 DC220
12Rated voltage of shunt releaseVAC220、DC220
13Average opening speedm/s3.5±1.5
14Average closing speedm/s3.5±1.5
15Three-phase points,closing phase of the samems≤3
16The main circuit resistanceu Ω≤120
17Manual maximum torqueN.m≤160
18Phase to phase center distancemm210+0 5



Tags relacionadas:

MENSAGEM ONLINE

Por favor, preencha um endereço de e-mail válido
Capitão. Não pode estar vazio

PRODUTOS RELACIONADOS

Nenhum resultado de pesquisa!

Contact Information

Indiana Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

New York Office

995 Green Hill St. Greenfield, IN 46140

1-800-1234-567

mail@demolink.org

Search

Este site usa cookies para garantir que você tenha a melhor experiência em nosso site.

Aceitar rejeitar