FLN36-24KV High Voltage SF6 Load Break Switch Spacing 230mm
1.FL(R)N36-24KV indoor high-voltage SF6 load circuit breaker is an indoor Switchgear with a rated voltage of 24KV It uses SF6 gas as arc extinguishing and insulation medium. It includes three positions: closing, opening and grounding. It has the characteristics of small size, easy installation and use, and strong environmental adaptability.
2.Combining FL(R)N36-24KV indoor high-voltage SF6 load circuit breaker with other electrical components can realize control and protection functions. It can be used for control and protection of electrical equipment in industrial and mining enterprises, civil power supply and secondary substations. Among them, the load switch-fuse combination electrical appliance matches the Transformer protection characteristics, which is particularly suitable for ring network power supply units.
3.FLN36-24KV/630-20 indoor high-voltage SF6 load circuit breaker (hereinafter referred to as load switch) and FL(R)N36-24KV/100-50 combination electrical appliance (hereinafter referred to as combination electrical appliance) comply with national standards GB3804 “3~63KV AC high-voltage load switch” (EQVIEC60265-1) and GBL6926 “AC high-voltage load switch-fuse combination electrical appliance” (EQVIEC420).
Operating environment
● Altitude: The maximum altitude of the equipment installation site is 1000m;
● Ambient air temperature: upper limit +40C, lower limit -15C;
● Ambient humidity: daily average relative humidity is not more than 95%, monthly average relative humidity is not more than 90%;
Earthquake: earthquake intensity does not exceed 8 degrees;
● Ambient air should not be obviously polluted by corrosive and flammable gases, water vapor, etc., and there should be no frequent severe vibrations.
| No. | Item | Unit | Data | |
| 1 | Rated voltage | KV | 24 | |
| 2 | Rated frequency | Hz | 50 | |
| 3 | Rated current | A | 630 | |
| 4 | Rated peak withstand current | KA | 50 | |
| 5 | 4s rated short time withstand current | KA | 20 | |
| 6 | Rated making current | KA | 50 | |
| 7 | Rated breaking current | Active load breaking current | KA | 630 |
| Breaking current loop | A | 630 | ||
| Cable charging breaking current | A | 10 | ||
| 8 | 1 min power frequency withstand voltage(phase to phase,to earth,fracture) | KV | 42/48 | |
| 9 | Lightning impulse withstand voltage(phase to phase,to earth,fracture) | KV | 75/85 | |
| 10 | Relative pressure of SF6 gas(20C Gp) | MPa | ≤0.04 | |
| 11 | Rated operating voltage (electric) | V | AC220、 DC220 | |
| 12 | Rated voltage of shunt release | V | AC220、DC220 | |
| 13 | Average opening speed | m/s | 3.5±1.5 | |
| 14 | Average closing speed | m/s | 3.5±1.5 | |
| 15 | Three-phase points,closing phase of the same | ms | ≤3 | |
| 16 | The main circuit resistance | u Ω | ≤120 | |
| 17 | Manual maximum torque | N.m | ≤160 | |
| 18 | Phase to phase center distance | mm | 210+0 5 | |